The Operation Steps of Syringe Filter
Preparations of Syringe Filter
(1)After the filter core and shell are thoroughly cleaned and sterilized, the filter is installed.
(2) After the installation of the Syringe Filter, the whole filtration system must be thoroughly flushed with clean water.
(3) After the whole filtration system is washed out, the filtration operation can be carried out.
Filtration and cleaning operation in production process
Open the exhaust valve, and slowly open the feed valve, introduce the material to be filtered. When the material flow out of the outlet of the exhaust valve, immediately close the exhaust valve, and slowly open the discharge valve.
In the initial stage of filtration, because the Syringe Filter element is still very clean and the filtering speed is very fast, the pressure in the filter is generally maintained at 0.05-1 Mpa. With the passage of time, the pressure in the filter can be gradually increased in order to maintain proper filtration rate. However, the maximum pressure in the filter cannot exceed the maximum operating pressure allowed by the filter element of different materials.
When the pressure in the Syringe Filter is higher and the filtration speed is slower, the filter operation should be stopped and the filter cleaned.
Backwash of Syringe Filter element
(1) For the fine filtration of mineral water and water treatment, clean water can be used for backwashing first, and then clean water filtered by terminal can be used for backwashing.
(2) For the filtration of fermentation broth and sugary broth such as and beverage, it is suggested that the clean oil-free compressed air should be used to blow back, then the clean water should be used to flush back, and then the filtered clean water should be used to flush back.
(3) When the filter element has been used for a long time and the filtering speed still does not recover satisfactorily after using the method mentioned above, the filter element can be discharged and immersed in NaOH solution of 2-4% concentration for 4-8 hours, then rinsed with clean water filtered by the terminal to the non-residual alkali solution, and then loaded into the filter to continue to use.
(4) For the users who are not three-shift continuous production, it is suggested that the filters should be washed before each shift leaves work, so as to avoid the long-term adhesion of dirt and bacteria clustering, which will affect the normal operation of the next shift.
Persona a contactar : Bruce Lu, +86 29 89284429
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de The Operation Steps of Syringe Filter Buscar en la categoria : Varios / Descuento Buscar en la categoria : steps, syringe, operation, filter |
Jueves 14 noviembre 2024
Dual Piston Volumatical Filling Machine FP425. available for working independently on each system. Cylinder Volume can be customized based on customer's requirement. FEATURES: - Filling volume can be customized based on customer's requirement - Each piston system can be set independently...
Autopack Co.,Ltd
- autopacker
- 33454 - Taoyuan City
- +88 6 33 68 98 06
Domingo 10 noviembre 2024
Nous sommes les principaux fournisseurs de boissons énergisantes comme Red Bull, requin, chargeur et bien d'autres.Nous pouvons également fournisseur can boissons comme Pepsi, Coca cola, Fanta, Sprite et autres produits.Nous fournissons également la meilleure qualité de l'eau minérale...
Vente en Gros
- 40400 - Kuala Lumpur
- +60 1 46 26 71 59
- +60 1 42 85 90 62
Domingo 10 noviembre 2024
♦ Functions * 2-channel temperature monitor * 1-channel fan speed control * Run time function * Fan fault alarm * Temperature fault alarm * Fan speed storage function * Auto fan speed control → 40°C: Low 50°C: Middle 60°C: High * Immediate visual indication of Fan/HDD...
Tengda Electronics Limited
- simeongao
- 518102 - hongkong
- +85 2 21 10 18 65