The Working Principle of Active Power Filter

Cantidad : 10000piece   Precio : 5-500USD/piece

Active power filter is a new type of power electronic device used to dynamically suppress harmonics and compensate reactive power. It can quickly track and compensate harmonics of different sizes and frequencies. Source filter can only passively absorb harmonics of fixed frequency and size, the active power filter can control and actively output the magnitude, frequency and phase of the current by sampling the load current and separating the harmonics and reactive power, and respond quickly to offset the corresponding current in the load, realizing dynamic tracking compensation. And it can not only make up harmonics but also make up reactive power and unbalance.

1. Theoretical basis of active power filter

Compared with the passive filter, the active power filter design has a good governance effect. It can mainly filter out multiple and high-order harmonics at the same time without causing resonance, but the price is relatively high. The actual application safety factor is very low. The international common practice is to use transformer boosting to ensure reliability. Relevant state departments also require the combination of transformer boosting and active filters to control high-voltage harmonics.

2. The active power filter working principle

The active power filter detects the load current through the current transformer, and calculates through the internal DSP, extracts the harmonic components in the load current, and then sends it to the internal IGBT through the PWM signal to control the inverter to generate a harmonic current with the size of the load. Equal and opposite harmonic currents are injected into the power grid to achieve the purpose of filtering.

The function of the command current detection circuit is mainly to separate the harmonic current component and the fundamental wave reactive current from the load current, and then reverse the polarity to generate the command signal of the compensation current. The function of the current tracking control circuit is to calculate the trigger pulse of each switching device of the main circuit according to the compensation current generated by the main circuit, and this pulse acts on the main circuit after the driving circuit. In this way, the power supply current only contains the active component of the fundamental wave, so as to achieve the purpose of eliminating harmonics and performing reactive power compensation. According to the same principle, the active power filter can also compensate the negative sequence current component of the asymmetric three-phase circuit.

The main circuit of the active power filter is generally composed of a PWM inverter. According to the different energy storage elements on the DC side of the inverter, it can be divided into voltage-type active filters (energy-storage elements are capacitors) and current-type active filters (energy-storage elements are inductors). The voltage-type active filter needs to control the capacitor voltage on the DC side during operation, so that the voltage on the DC side remains unchanged, so the output of the AC side of the inverter is a PWM voltage wave. The current-type active filter needs to control the inductor current on the DC side during operation, so that the current on the DC side remains unchanged, so the output of the AC side of the inverter is a PWM current wave. The advantages of the voltage-type active filter are that the loss is less and the efficiency is high. The current will produce a large loss in the internal resistance of the inductor.

If you want to know more kinds of power transducer, please visit our website.

Ubicación : No.5 Dongmeng Road, Nanzha Street, Jiangyin City, Jiangsu Province, China., 214405 Jiangyin,
Persona a contactar : Tim MA, 86 510 86179966

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
The Working Principle of Active Power Filter

Buscar en la categoria : Varios / Descuento
Buscar en la categoria :
active, power, principle, working, filter
Francia 59590 B2B Servicios
GATE VALVE

Wednesday 14 September 2016

Cantidad : 5000 - Precio : 50,00 €

Gate Valves (F7 Type) DIN Standard F7 Gate valves / (Length acc.to DIN EN 558-1,face to face series 26 ) DIN F7 Gate valve DIN Absperrschieber F7 DIN Válvulas de compuerta F7 DIN F7 šoupátko stavební délka dle DIN EN558-1 serie 26 DIN Standard F7 sluseventil (lengde iht. DIN EN 558-1...)

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935
New Design!! MSW-104 Bubble Bath Spa Massager Full Body Mattress Ozone Massage Non-Slip...

Monday 07 March 2016

Bubble Bath Spa Massager MSW-104 Bubble Bath Spa Massager is a new generation of home spa massager and is optimized for use in bath with the quality of tranquility, relaxing and luxury life. Configuration of MSW-104 is One-Touch Control Panel with Minimal and fashionable design...

LienJie International Ltd.

  • 414 - Taichung City
  • +886 4 23367128
Francia 528500 Higiene / salud
Dental Chair manufacturing and trading combo

Sunday 12 July 2015

Cantidad : 1 - Precio : 2 000,00 €

Specification: Power Voltage 220V-50HZ Motor Voltage 24V Water Pressure 0.2Mpa-0.4Mpa Air Pressure 0.5Mpa-0.8Mpa Ubicación : Foshan City , 528500 Foshan , Persona a contactar : Nature Mai Mai , +15 0 19 61 17 04

France Skylight International Limited

  • 528500 - Foshan
  • +15 0 19 61 17 04