Varios / Descuento

What Causes Pollution Of HPLC Column?

Usually, the sample contains something that is not of interest to the analyst. Salt, lipids, lipid-containing substances, humic acid, hydrophobic proteins, and other biological substances are some substances that may interact with the HPLC column in use.

These substances have less or greater retention values than the analyst's target. Substances with smaller retention values, such as salts, are generally washed into excellent spectral columns as empty volumes. The interference of these non-target products can be detected by detectors and can form chromatographic peaks, bubbles, baseline upward shifts or negative peaks.

If the sample composition is strongly retained in the HPLC column and the mobile phase solution composition is not enough to elute these substances, after repeated sampling, the substances adsorbed on the surface of the column will usually accumulate on the column header. These behaviors are usually detected only through parallel experiments. Samples with moderate retention values can be washed out slowly and exhibit broad peaks, baseline disturbances, or baseline drift.

Sometimes these adsorbed sample components accumulate to a certain extent to enable them to start forming new stationary phases. The analyze can interact with these impurities to form a certain separation mechanism. Retention time will fluctuate and tailing will occur. If enough pollution is produced, the back pressure of the HPLC column can exceed the maximum pressure that the pump can withstand, making the column unable to work and generating empty volume in the blocked place.

Ubicación : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Persona a contactar : Bruce Lu, +86 29 89284429

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
What Causes Pollution Of HPLC Column?

Buscar en la categoria : Varios / Descuento
Buscar en la categoria :
what, pollution, hplc, column, causes
Marruecos 20000 Construcción
Maroc, vente, fournisseurs, geomembrane, grossistes, producteurs, import-export

Monday 20 July 2015

Maroc, vente, geomembrane, fournisseurs, distributeurs, importateurs, producteurs, grossistes, import-export. Société italienne spécialisée en production de GEOMEMBRANE cherche importateur exclusif au Maroc La société cherche un partenaire sérieux et Menut des moyens logistiques...

impresa in marocco sarl

  • 20000 - CASABLANCA
  • 06 29 90 85 75
Taiwán 414 Higiene / salud
New Design!! Bubble Bath Spa Massager Full Body Mattress Ozone Massage Non-Slip Soft Ma...

Wednesday 23 March 2016

Cantidad : 200 - Precio : FOB Keelung, Taiwan

No Matter you looking for a beauty care or healthcare product, our Bubble Bath Spa Massager have a fully functions to meet your any request. You might be curious that what the function of spa massager it is?! Merits of MSW-104 are as follows; 1. Based on the principle of explosion...

LienJie International Ltd.

  • 414 - Taichung City
  • +886 4 23367128
Hong Kong 523929 Higiene / salud
Rooman Home Air Purifier AC300

Tuesday 18 August 2015

Cantidad : 200 at lea - Precio : To be discussed

Key Specification: - Color: Various color can be chosed - Input Voltage: 120~240V - Rated Power: 50-60HZ - Power (W): 36~55W - Noise Level: 25~55dB - Display Mode:LED - Control Mode: Touch screen - CADR: 320m³/H - Purifying Rate: 99.7% - Length Of Power Cord: 2...

Rooman Electrical Appliances Co., Ltd.

  • Rooman1
  • 523929 - Dongguan
  • +13 6 62 88 32 70