BMS for ESS
The energy storage battery management system consists of battery pack management unit (BMU module), battery cluster management unit (RCU module), system management unit (SCU module) and system display management unit (MM10 module). This lithium bms battery management system supports a maximum of 1500V energy storage system.Topology of BMS ESS Features of BMS for ESS
3+1 level structure
Online program upgrade
Support bidirectional IO ports to achieve automatic address coding
Multi-ports environment supervision devices data access
Function of BMS for ESS
Battery information management
Cluster status monitoring
Cluster status analysis
Safety control and protection
Energy control management
Battery maintenance management
Communication port and protocol
Specification of BMS of Battery for ESS
BMU Module
Category |
Item |
Specification |
||||
Working environment |
Temperature |
Operating temperature:-20~+65°C |
Storage temperature:-40~+125°C |
|||
Working power |
Voltage/Power consumption |
Rated voltage:9~32Vdc(reverse connection protection) |
Rated power consumption: 120mW (without load) |
|||
Communication |
CAN |
Support 1-channel non-isolated CAN |
Communication rate: 250kbs |
|||
Collection |
Cell voltage collection |
Collection range: 0~5V |
Collection resolution: 1mV |
Collection accuracy: |
Collection rate:100ms |
Electrical isolation: |
+10≤t≤+45 °C, the accuracy ≤5mV; |
4149Vdc/2934Vac (8mm) |
|||||
-40~≤t≤125°C, the accuracy ≤8mV |
|
|||||
Cell temperature collection |
Collection range: -40~+125°C |
Collection resolution: |
Collection accuracy: |
Collection rate:200ms |
|
|
0.1°C |
-20≤t≤+65°C, the accuracy≤1°C; |
|
||||
|
-40≤t≤+125°C, the accuracy≤2°C |
|
||||
Cell equalization |
Cell equalization control |
Support 24-channel cell passive equalization |
Equalization resistance: 33Ω |
Equalization temperature rise:≤45°C |
RCU Module
Category |
Item |
Specification |
|||||
Working environment |
Temperature |
Operating temperature:-20~+65°C |
Storage temperature:-40~+125°C |
||||
Communication |
CAN/RS485 |
Support 1 isolated CAN and 1 non-isolated CAN |
2 isolated RS485 |
||||
Collection |
Total voltage |
Collection range: 0~1500V |
Collection resolution: 0.1V |
Collection accuracy: |
Collection rate: |
Electrical isolation: |
|
collection |
Total voltage<1000V (≤±1%FS)</span> |
100ms |
4149Vdc/2934Vac (8mm) |
||||
|
Total voltage ≥1000V (≤±0.5%FS) |
|
|
||||
Total current |
Collection range: ±1200A |
Collection resolution: 0.1A |
Module circuit collection accuracy: ±1200A, accuracy ±1%FS |
Collection rate: |
|
||
collection |
200ms |
|
|||||
Insulation collection |
Collection range: 0~10MΩ |
Collection accuracy: accuracy≤3% (500V~1500V, ≥600KΩ) |
Collection rate: 60s |
|
|||
(adjust according to the Y capacitance value of the PCS device) |
|
||||||
Temperature collection |
Collection range: -40~+125°C |
Collection resolution: 1°C |
Collection accuracy: |
Collection rate: |
|||
-20~+65°C, accuracy≤1°C; |
200ms |
||||||
-40~+125°C, accuracy≤2°C |
|
||||||
Monitoring capability |
1 RCU module can max. manage 32 BMU modules |
SCU Module
Category |
Item |
Specification |
|
Working environment |
Temperature |
Operating temperature: |
Storage temperature: |
-20~+65°C |
-40~+125°C |
||
Communication |
LAN communication |
Communication rate: 10M/100M |
Electrical isolation: 3000Vdc |
CAN communication |
Communication rate: 250kbs |
Electrical isolation: 2500Vdc |
|
RS485 communication |
Communication rate: 9600kbs |
Electrical isolation: 2500Vdc |
|
RS232 communication |
Communication rate: 9600kbs |
Electrical isolation: 2500Vdc |
|
Storage |
Data record |
On-board eMMC |
External expansion TF |
storage space: 8G |
card storage space: 0~128G |
||
Insulation |
Communication |
LAN:3000Vdc |
CAN/RS485/RS232:2500Vdc |
Monitoring capability |
1 SCU module can max. manage 30 RCU modules |
MM10 Module
Category |
Item |
Specification |
|
Working environment |
Temperature |
Operating temperature: |
Storage temperature: |
-10~+60°C |
-20~+70°C |
||
Working power |
Voltage/Power consumption |
Rated voltage:9~30Vdc |
Rated power |
consumption:10W |
|||
Communication |
LAN |
1 isolated LAN |
Communication rate: |
10M/100M |
|||
Basic parameter |
micro USB port |
Support 1-channel micro USB for system |
|
programming and ADB debugging |
|||
Screen |
10.1 inch display |
Capacitive touch screen |
|
Storage |
Data record |
eMMC storage space:8G |
TF card storage space: |
0~128G |
|||
Hardware parameter |
CPU processor |
RK3288/4 core frequency 1.6GHz |
|
Run system |
Android 7.1 |
||
GPU |
ARM Mail-T764 |
Persona a contactar : huasu huasu, 0571 87967915
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de BMS for ESS Buscar en la categoria : Búsqueda/compra Buscar en la categoria : |
Viernes 19 abril 2024
Cantidad : 108
Product Details Bed Type : Panel Layer : 2 layers Frame Material : Metal Color : Pink, Blue, Cream white, Browm… Headboard Included: Yes Under bed Storage : No Product Care : Wipe with a clean, damp cloth Painted frame · One set include - Headboard. - Footboard. - Two...
Qui Phuc Company Limited
- Luck06
- 700000 - Ho Chi Minh
- +84 9 86 58 28 62
Lunes 20 julio 2015
maroc, vente, plastique recyclée, fournisseurs, distributeurs, importateurs, producteurs , grossistes, import, export. Société italienne spécialisée en production d'un polymère innovant produits parmi le recyclage de polyoléfine et polypropylène cherche importateurs utilisateurs...
impresa in marocco sarl
- 20000 - CASABLANCA
- 06 29 90 85 75
Miércoles 20 mayo 2015
AI101P Single Port KVM over IP The KVM over IP technology (IP-KVM) combines digital remote KVM access via IP networks with comprehensive and integrated system management. The IP-KVM defines a new class of remote KVM access devices that can save your money, time, space, and equipment...
ACAFA Information Co.
- epanio
- 335 - Dasi Township
- +88 6 33 07 13 00