How to Clean the HPLC Columns
The reversed-phase HPLC columns may be repeatedly injected into a sample containing a strongly retained material, and in particular, the sorbent components such as large molecular weight or hydrophobic biological flow proteins and strong alkaline substances may be adsorbed on the silica medium. In addition, some mobile phase additives such as ion-pairing test reagents and reactants can adsorb on the filling surface and change their properties. Contaminated columns can cause peak shape differences, poor retention of repeatability, high back pressure, and baseline drift. Typically, these columns can be cleaned using organic solvents or agents capable of destroying contaminants and binder phases or silica surfaces. The users should be careful when using reagents that are corrosive or destructive to the binding phase. Additionally, the use of sample preparation minimizes contact between the HPLC columns and undesired materials to reduce contamination. We suggest using the HPLC protect column as pre-filter. Use Pre-filter, HPLC protect column, can reduce pollution from contamination and possibly store the analytical HPLC columns.
Persona a contactar : Bruce Lu, +86 29 89284429
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de How to Clean the HPLC Columns Buscar en la categoria : Varios / Descuento Buscar en la categoria : clean, columns, hplc |
Tuesday 14 April 2026
Cantidad : 108
Product Details Bed Type : Panel Layer : 2 layers Frame Material : Metal Color : Pink, Blue, Cream white, Browm… Headboard Included: Yes Under bed Storage : No Product Care : Wipe with a clean, damp cloth Painted frame · One set include - Headboard. - Footboard. - Two...
Qui Phuc Company Limited
- Luck06
- 700000 - Ho Chi Minh
- +84 9 86 58 28 62
Friday 06 February 2015
Cantidad : 100MT/Mont
Chemical Name: L-2-Amino-3-hydroxybutyric acid; Structure Formula: Molecular Formula: C4H9NO3 Molecular Weight: 119.12 Cas No: [72-19-5] Characteristics: White crystalline powder Quality Standards: USP24, FCCIV, AJI97 and etc. Item Specification USP24 FCCIV...
Zhaocounty Granray Bioproducts Co.,Ltd
- 051530 - NanBaiShe
- 8631180826581
Saturday 18 July 2015
Especificaciones: Tamaño de hoja: 210mm x 297mm, Internacional A4 Calidad: 100% importado de pulpa de madera virgen Blancura = 102-104%, blanco natural Capacidad: Copying100ppm alta velocidad, Laser Capaz, Especificaciones de chorro: Tamaño de hoja: 210mm x 297mm, Internacional A4 Calidad...
PAPERY (THAILAND )CO LTD
- 10400 - Bangkok
- 098765443533