Construcción

Low Temperature Chiller LN -60-10

We know that the low temperature chillers are complicated equipment. Even the switch process, if not according to the standard of operation or with no special maintenance, will inevitably lead to a decline in the refrigeration efficiency of the low temperature chillers and will greatly reduce the service life of the them. Here, we will talk about major attention matters when enterprises use low temperature chillers!

1. Refrigerant leakage

Refrigerant leakage will not only affect the refrigeration efficiency of low temperature chillers, but also affect the health of people in and out of the engine room, so the issue of refrigerant leakage must be noted.

2. Pay attention to the load of the low temperature chillers

The large load of low temperature chillers, or overload phenomenon which is more than the rated load, will bring about serious problems including refrigeration efficiency decline, bigger noise, bigger vibration amplitude, excessive consumption of resources, decline in service life and so on which need to pay attention to!

3. Temperature and pressure

It can be said that the parameters related to temperature and pressure are the most important parameters of low temperature chillers. Enterprises should pay attention to the parameters related to the temperature and pressure of the low temperature chillers, and solve them in time, so as to avoid affecting the normal operation of the low temperature chillers.

Paying attention to the points mentioned above has extraordinary importance for extending the service life of low temperature chillers ,and improving the refrigeration efficiency and the use safety of low temperature chillers.

-60℃~-10℃

Technical Parameters:

Low circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeration bath circulators, Refrigeration circulator, Refrigeration thermostats, Refrigeration bath circulator, Low temp freezer, Freezer, Low freezer, Low chiller, Freezer chiller, Cold trap, Immersion cooler, Low temp bath, Bath thermostats.


Low Temperature Chiller LN -60℃~-10℃LNEYA chiller freezer application

Model LN-6W LN-10W LN-15W LN-20W LN-30W LN-40W LN-60W LN-90W LN-120W LN-180W
Temperature Range -60°C~ -10°C
Cooling Capacity
At -40°C
12kw 20kw 30kw 40kw 60kw 80kw 120kw 180kw 240kw 360kw
10320Kcal/h 17200Kcal/h 25800Kcal/h 34400Kcal/h 51600Kcal/h 68800Kcal/h 103200Kcal/h 154800Kcal/h 206400Kcal/h 309600Kcal/h
Cooling Capacity
At -55°C
6kw 10kw 15kw 20kw 30kw 40kw 60kw 90kw 120kw 180kw
5160Kcal/h 8600Kcal/h 12900Kcal/h 17200Kcal/h 25800Kcal/h 344000Kcal/h 51600Kcal/h 77400Kcal/h 103200Kcal/h 154800Kcal/h
Circulation Pump Info 6.6m³/h 9m³/h 15m³/h 15m³/h 25m³/h 25m³/h 25m³/h 35m³/h 35m³/h 50m³/h
2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max 2.5bar max
Inlet&outlet connection size DN-25
PN-10
DN-25
PN-10
DN-32
PN-10
DN-32
PN-10
DN-40
PN-10
DN-40
PN-10
DN-40
PN-10
DN-50
PN-10
DN-50
PN-10
DN-65
PN-10
Cooling Water at 30 degree 10m³/h 14m³/h 20m³/h 25m³/h 30m³/h 35m³/h 50m³/h 70m³/h 90m³/h 120m³/h
Cold Storage tank (optional) 200L 350L 500L 750L 1000L 1200L 1500L 2200L 3000L 4000L
Expansion tank(standard) 100L 175L 250L 350L 500L 600L 750L 1000L 1350L 1800L
Compressor Dorin semi-closed compressor Dorin compressor/HANBELL、Fusheng、Bitzer screw compressor
Operation Panel 7-inch color touch screen display, temperature curve record
Control System SIEMENS S7 PLC&Module,Set temperature difference of refrigeration on & off
Closed Circulation System The whole system is a full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature
Circulation Pump LNEYA Mangetic Pump/German Brand Mangetic Pump
Evaporator Danfoss/KAORI plate heat exchanger
Condenser Casing type water-cooled condenser / tube-type water-cooled condenser
Intermediate heat exchanger Danfoss/KAORI plate heat exchanger
Refrigeration accessory Oil separators, drying filters, expansion valves, refrigeration solenoid valves, pressure control, mirrors, etc. all use Emerson / Danfoss and other brands
Electric AC contactors, intermediate relays, circuit breakers, thermal relays, etc. are Schneider / ABB brand
Refrigerant R404A/R23 mixture,optional: R125/R23 mixture
Secondary refrigerant No corrosive liquid, ethanol water, heat transfer oil etc.
Safety Protection High pressure protect; water supply cut-off protection; over-current protection; leakage protection; sequential and phase failure protection; High temperature protection; Sensor Failure protection; Liquid low level protection etc. multi-safety protection
Level Indicator Adopt glass liquid level indication
Piping material Expansion tank, cold storage tank and circulation pipeline are all made of SUS304
Case material Channel steel + square tube + cold rolled plate sealing plate spray 7035
Dimension cm 100*150*185 205*145*205 205*145*205 205*145*175 245*145*205 300*160*225 350*160*205 400*160*225 500*200*225 650*200*225
Power 14kW 18kW 26kW 35kW 52kW 69kW 104kW 152kW 200kW 300kW
dB within 75dB within 80 dB within 90 dB
Weight (kg) 850 1000 1200 1450 2000 2400 3000 3600 4200 5600
Optional Optional outside touch screen display controller (separated), the communication line distance is 10 meter
Optional Optional explosion-proof touch screen control system (ExdeIIBT4), the communication line distance is 15 meter

why choose lneya

Ubicación : No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu ,China.Zip Code:214142, 214115 Wuxi,
Persona a contactar : Tony Tony, 0510 82303782

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Low Temperature Chiller LN -60-10

Buscar en la categoria : Construcción
Buscar en la categoria :
chiller, temperature
Taiwán 335000 Audio / video
Foto no disponible

Miércoles 04 noviembre 2015

HDMI USB Extender over HDBaseT - CAT5e/6/7 Support Touch Screen [HDU700] is the unique and high-performance HDBaseT AV/PC Extender supporting HDMI, USB HID, high-quality S/PDIF Audio Line Out and IR at the best strengthened competitive price in the market. By using HDBaseT...

ACAFA Information co,Ltd

Taiwán 335 Audio / video
150M VGA KVM Chainable CAT.5e/6 Extender over IP- ACAFA TV150A

Martes 20 mayo 2014

Cantidad : 1000 - Precio : N/A

TV150A VGA KVM Chainable Extender over IP with Audio is the innovative solution applied for a wide variety of HID devices extending in terms of excellent compatibility of “True USB emulation” technique, even supports the latest 10- point touch screen, and signals extended...

ACAFA Information Co.

  • epanio
  • 335 - Dasi Township
  • +88 6 33 07 13 00
España 23520 Alimentación
Aceite de Oliva Virgen Extra España Ecológico 100% calidad

Jueves 14 noviembre 2024

Oleícola San Francisco es una empresa especializada en la elaboración de Aceite de oliva Virgen Extra de la más alta calidad. Exportamos nuestros mejores aoves a todos los continentes. La gama ECOLÓGICA "San Francisco olive ecológico" se elabora con aceitunas de variedad Picual...

OLEICOLA SAN FRANCISCO S.L.