PHASES - 2612 Anuncios

China 710077 Varios / Descuento
Normal Phase HPLC Column and Reverse Phase HPLC Column

Viernes 05 julio 2019

When the polarity of the stationary phase is greater than the polarity of the mobile phase, it can be called normal phase partition chromatography or simply normal phase chromatography. If the polarity of the stationary phase is less than the polarity of the mobile phase, it can be...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
C8 HPLC Columns

Jueves 04 julio 2019

C8 HPLC columns are used to isolate many organic compounds, which are one of the reversed phase silica gel columns. The maintenance of C8 HPLC columns requires organic solvents. Chromatographic grade methanol is recommended and different brands of chromatographic columns should be...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Polymeric HLB SPE Cartridges

Jueves 04 julio 2019

The filler of polymeric HLB SPE cartridges produced by a special copolymerization technology contains a certain proportion of the hydrophilic group and the hydrophobic group. Hydrophobic divinyl benzene structures retain nonpolar compounds and hydrophilic n-vinyl pyrrolidone structures...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
How to Use and Maintain Reversed-Phase HPLC Columns(1)

Jueves 04 julio 2019

(1) When loading and unloading or replacing the HPLC columns, the action should be light and the joint should be tightened properly. Strong mechanical vibration must be prevented to avoid voids in the bed. (2) If the instrument is used for routine analysis, the sample type is limited...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
How Does SPE Extraction Work During the Whole Process?

Jueves 04 julio 2019

Activation, also known as solvation, add a suitable solvent to expand the functional groups on the adsorbent and remove possible interferences on the adsorbent. Equilibrium, remove the activated solvent to create a suitable solvent environment for sampling. Usually, use the same solvent...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Guide To Select Flash Column

Miércoles 03 julio 2019

Flash column chromatography is an efficient way to separate complex mixtures of compounds in the lab. we use compressed air to push the solvent through the column when we are running flash columns. It can help provide better separation and cut down the running time as while. Flash...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
QuEChERS for Agricultural Residue Pretreatment

Martes 02 julio 2019

The average sample addition recovery rate of QuEChERS method is higher than 85%, with fewer impurities interfering with the detection of the target substance, a small amount of solvent, simple and fast operation, which will be the preferred pretreatment method for routine detection...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Cleaning Silica Gel Bonded HPLC Columns

Martes 02 julio 2019

The key to regenerating contaminated HPLC columns is to know the nature of the contaminants and to find the right solvent to remove. If contamination is caused by the accumulation of strongly retained materials during repeated injections, simple steps to remove these contaminants...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
A Brief Introduction To Syringe Filter

Lunes 01 julio 2019

This is a useful weapon for experimental analysts to filter micro-samples quickly and effectively, such as sample pre-filtration, clarification, and filtration of particles, liquids, and gases sterilizing, etc. The structure of Hawach syringe filter The structure of Hawach syringe...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
The aim of flash column chromatography is to separate components from the mixture and...

Lunes 01 julio 2019

The aim of flash column chromatography is to separate components from the mixture and purify it. Briefly, flash column chromatography allows samples to be separated through columns filled with gels. Flash column chromatography has been widely used in organic chemistry since its inception...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Product Highlights & Core Technique of Filter Membranes

Lunes 01 julio 2019

Usually, there are two essential properties that end users are the most—extractability of the impurities and advantages of microporous polymer membranes. Extractability of The Impurities Scientific laboratories mostly apply the membrane product to filter samples, mobile phase, and...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Principles for Selecting SPE Cartridges Specifications

Lunes 01 julio 2019

After selecting the type of SPE cartridges, we have to determine the specifications of the SPE cartridge. The principle of selecting the SPE cartridge specification is to first ensure that the SPE cartridge packing has sufficient capacity to retain the target compound 100% on the column...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Moteurs Electriques tri-phasés Neufs

Sábado 29 junio 2019

Cantidad : 16 - Precio : 200 à 400,00 €

Je vends des moteurs electrique Tri-Phase Neufs de marque AEG 7 de 7.5KW = 400,00 €/u 6 de 4 KW = 200,00 €/u 3 de 5.5 KW = 300,00 €/u Ubicación : ZA OCEALIM Av St EXUPERY, 87270 COUZEIX, Persona a contactar : Ahmed Ennjimi, 05 55 37 13 44

FRAMAR Industrie

  • framar
  • 87270 - COUZEIX
  • 05 55 37 13 44
  • 06 63 54 16 17
China 710077 Varios / Descuento
Normal & Reversed HPLC Column

Viernes 28 junio 2019

Stationary Phase & Mobile Phase The stationary phase is used to separate the substances, which is packed into HPLC Column directly; Mobile phase is the carrier, which carries the substances into the stationary phase and goes through the stationary phase. It is gas in the vapor phase...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
The Brief Introduction to Flash Column

Viernes 21 junio 2019

Flash chromatographic column, also called rapid chromatographic column(rapid column crossing, which means gradient elution, decompression or pressurization of the column), medium pressure chromatographic column(for example, rapid elution is achieved by pressurizing with nitrogen and...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
How does SPE Cartridge Work?

Viernes 21 junio 2019

Normally SPE cartridge has two basic adsorption modes: target compound adsorption mode, impurity adsorption mode; 5 operation modes: gravity operation, manual positive pressure, centrifuge, negative pressure and positive pressure mode. Now let's review the whole process step by step...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Introduction to Vacuum Filtration

Jueves 20 junio 2019

Basic Knowledge of Vacuum Filtration Based on the principle that under the same pressure (vacuum degree), the vaporization temperature of the water is lower than that of oil, scientists make practical equipment which is called vacuum filter. In fact, vacuum filtration is the most...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
The Differences Between PVDF and PTFE Membrane

Jueves 20 junio 2019

PTFE stands for Poly Tetra Fluoroethylene. People generally call it non-sticking lining or easy-cleaning material. The material of PTFE has the characteristics of antiacid and antisolvent, which means it is hardly insoluble in all solvents. And PTFE is heat-resistant and with low...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
The Basic Knowledge of Selecting the Most Suitable Flash Column

Miércoles 19 junio 2019

The most important process of the whole purification is selecting the most suitable Flash column. And now we will talk about the key content of the column: stationary phase. Stationary phase, commonly known as filler, is the most central part of chromatography. When we choose the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Introduction of HPLC Column From Hawach

Miércoles 19 junio 2019

Hawach Scientific sorts HPLC out of two series which are Xchroma and Echroma. Xchroma columns possess many and complete types of stationary phase(23 in total) with reliable qualities, while another one is cheaper among lower prices. Essential Technical Parameters Naming Rule It consists...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
The Brief Introduction to SPE Cartridges

Miércoles 19 junio 2019

SPE cartridges, with a full name of Solid Phase extraction cartridges, is also called the SPE column( solid phase extraction column). The solid phase extraction column/cartridges is a pretreatment device for the sample being analyzed, which developed from the chromatographic column...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 610000 Bienes de equipo
Carrier air compressor 06na2300s5ec-a00

Martes 18 junio 2019

As reference: TYPE: Screw POWER: 415v / 3 phase Max operating amps: 221 amps FEATURES: 134a refrigerant Other Types: Carrier air compressor 06NA2300S5EC-A00 Carrier air compressor 06NW2300 Carrier air compressor for PERFORMANCE 17 24ACB7 Carrier air compressor for PERFORMANCE...

A&S Aerodynamic Co., Ltd

  • 610000 - chengdu
  • +86 28 65376575
  • 862865376575
China 214115 Construcción
Ultra Low Temperature Recirculating Chillers LC -25-5

Martes 18 junio 2019

After running for a period of time, the normal operation of ultra-low temperature circulating water chiller needs comprehensive maintenance and maintenance. For many enterprises, due to the weak consciousness of daily maintenance, the cryogenic cycle water chiller has been used for...

China 214115 Construcción
Low Temperature Chiller LN -60-10

Martes 18 junio 2019

We know that the low temperature chillers are complicated equipment. Even the switch process, if not according to the standard of operation or with no special maintenance, will inevitably lead to a decline in the refrigeration efficiency of the low temperature chillers and will greatly...

China 710077 Varios / Descuento
ETo obtain accurate separation of your sample, mobile phase, and other liquid, the perf...

Sábado 15 junio 2019

ETo obtain accurate separation of your sample, mobile phase, and other liquid, the perfect tool that you need is laboratory filters. An analysis of physical specifications and performance specifications is required when selecting filters. Physical specifications for laboratory filters...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Learn about SPE Cartridges

Sábado 15 junio 2019

What is SPE Cartridge? The term SPE cartridges is short for Solid Phase Extraction cartridge. It is a kind of sample preprocessing equipment (extract, separate and concentrate) which is developed from the chromatographic column. SPE cartridge is mainly used for preprocessing of the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
HPLC Column Silicone Matrix Properties and Scope of Application

Viernes 14 junio 2019

Hawach introduced the properties and application range of HPLC column stationary phase in the silica gel matrix. Silica gel matrix: Silica gel, weakly acidic, has a strong memory, used to separate non-polar, weakly acidic compounds, oils, etc.; C18, a silica-based uncapped reversed-phase...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
NH2 HPLC Columns

Jueves 13 junio 2019

NH2 HPLC columns can be used in the positive phase or in the negative phase, but it should be noted that the positive phase solvent and the negative phase solvent are usually not mutually soluble. New NH2 HPLC columns are preserved in the positive phase environment under normal circumstances...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Hawach QuEChERS Solutions

Jueves 13 junio 2019

Package 1 QuEChERS extracting pesticide residues from plants Extraction box: 50 ml centrifuge tube + AOAC/EN salt pack 2 kinds of buffer salts: General buffer salt for phase-separation and pH-adjustment; Anhydrous magnesium sulfate completely separates water in the matrix from the...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Varios / Descuento
Installation of the HPLC Column

Martes 11 junio 2019

The installation of the HPLC column should be carried out in the following three steps: a. Unpack the HPLC column and confirm the type, size, date of manufacture, and solvent stored in the column. b. Unscrew the sealing plug from the joints at both ends of the column and put it back...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Nombre de resultados por pàgina : 6 30 150

Búsqueda PHASES